ULCAP320, ULCAPT340, ULCAH330 - Intelligent addressable Cooper Fire Alarm Detectors

ULCAP320 family is a range of intelligent addressable sensors that have been specifically designed to operate with Eaton intelligent addressable fire systems. All detectors are third-party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors).

High sensitivity of fire which are designed for all types of buildings

Our addressable range has multiple options for intelligent addressable detectors. All detectors are designed for optimum functionality in mid-large-sized builds. They are all soft addressed and have integral short circuit isolators. Check our Cooper Home Page for more info about the Cooper as a fire alarm brand

Code CAP320CAPT340CAH330
Description Optical smoke detector Photo-thermal detector Multi-mode heat detector
Standards EN54 Pt7 2000 + A1:2002, EN54 Pt17 EN54 Pt7 2000 + A1:2002, EN54 Pt17 EN54 Pt7 2000 + A1:2002, EN54 Pt17
Operating volatage 18V dc to 30V dc 18V dc to 30V dc 18V dc to 30V dc
Standby current 220μA (max) 220μA (max) 220μA (max)
Alarm current 5mA (max) 5mA (max) 5mA (max)
Specification
Mounting position Ceiling in open areas Ceiling in open areas Ceiling in open areas
Mounting options Surface mount with CAB300 base Surface mount with CAB300 base Surface mount with CAB300 base
Area coverage 100m2 (subject to local standard) 100m2 or 50m2 (subject to local standard) 50m2 (subject to local standard)
System wiring Min. 1.5mm, 2 core loop or spur Min. 1.5mm, 2 core loop or spur Min. 1.5mm, 2 core loop or spur
Environment
Operating temperature -10°C to +60°C -10°C to +50°C -10°C to +50°C

Our dedicated team can do it on your behalf:

We can install, commission, and operate all cooper fire alarm panels. The Commercial Office for Importing has been into the field of importing and distributing cooper fire alarm with alla support since 1998.

The Commercial Office in Cooper fire alarm brings years of expertise in fire alarm development. Our team was founded in 1998, as we started with Menvier, JSB, Nugelec, and Eaton at the end. We have been working closely since with customers utilizing the Cooper fire alarm system in Egypt. 

We are based in Cairo, Egypt at 162 Tahrir Square. Our team always ensures leaving an amassed reputation within the Cooper fire alarm products. As well, we have completed a lot of projects within the fire alarm sector like hospitals, transport hubs, and government buildings. At the moment, we are holding on to maintenance contracts in larger medical facilities like Sanofi Aventis Pharma and Amoun Pharmaceuticalwhich utilizes Cooper as a fire alarm product.

Tags :
Addressable Fire Alarm,CAP320,cooper fire alarm,Smoke Detectors
Share This :